MAX VCBsMAX Electric offers a wide range of Vacuum Circuit Breaker, which
delivers excellent performance. In order to prevent fires and power
surges, these circuit breakers are used in areas where electric crisis
may occur. These circuit breakers finds application in medium voltage
power system. The different types of Vacuum Circuit Breakers offered by
us are:RANGES- 12 KV VCB Outdoor Roof Bush Panel
- 11kV Double Bus Bar VCB Panel with dual sequence isolator for each incoming source
- 22kV Integra Series VCB Panels
- Outdoor Panel With TVM Vacuum Circuit Breaker
- Ring Main Units upto 36kV Indoor & Outdoor
ADVANTAGES- Compact and robust design
- Easy integration in cubicle
- High safety, reliability and continuity of service
- Long durability
- Low-maintenance
- Low contact transition resistance
- Up to 10,000 switching operations (M2)
- Optional: Integrated digital unit
APPLICATIONS
Control and protection of the power supply to motors, transformers, capacitors and other feeder circuits. Designed for indoor / outdoor use and is particularly suitable for- Electric power plants
- Substations
- Industrial plants
- Commercial buildings
- Pumping stations
- Pipeline stations and
- Transportation systems.
- Large infrastructures: Airports, railways, etc.
- Installation in AIS cubicles
- Power stations: Wind farms
- Utilities: Primary distribution substations
- Industry: Chemical, Iron and steel, automobile, etc.
The VMAX Series VCBs are available at rated voltages of 6.6 to 36 kV, with rated short-circuit breaking capacities from 25 to 40 kA. SALIENT FEATURES HIGH RELIABILITY: Testing is performed by an independent testing team. Fully Insulated Design and all the operations are behind the closed doors.All components, such as current transformers, voltage transformers and multifunction relays are made of the highest quality materials.Our new generation design has reduced the number of parts, which reduces the chance of failure.SAFETY: Compartment partitions and an automatic shutter system completely isolate live parts.Comprehensive interlocking mechanisms are used for Safe Operations. MAX VCBs are designed to withstand the huge pressure and burning effect of the arc to withstand in the event of an internal arc fault.HIGH PROTECTION: Specially designed Multiple Protection Relays are installed to provide protection, measurement, communications and control functionality.FLEXIBLE DESIGN FOR EASY INSTALLATION: Flexible features like Readily extensible, Panels with main circuit and control cable entry from either the top or bottom are available for easy installation. Installation and testing duration are considerably reduced as the panel is tested in the factory and then delivered as a complete unit.
STANDARD TECHNICAL FEATURES OF MAX SERIES CIRCUIT BREAKER PANELS
MAX STANDARD VCB TECHNICAL DATA
|
TYPE
|
VMAX6
|
VMAX7
|
VMAX12
|
VMAX17
|
VMAX24
|
VMAX36
|
Rated Voltage (kV)
|
6.6
|
7.2
|
12
|
17.5
|
24
|
36
|
Frequency (Hz)
|
50
|
50
|
50
|
50
|
50
|
50
|
Rated Insulation level (1
min) kVrms
|
20
|
20
|
28/36
|
36
|
50
|
70
|
1.2/50 micro sec. impulse
(kV peak)
|
60
|
60
|
75/95
|
95
|
125
|
170
|
Rated Current A
|
630/1250/2000
|
630/1250/2000
|
630/1250/2000
|
630/1250/2000
|
630/1250/2000
|
630/1250/2000
|
Rated short time current
rating (3 Sec)
|
16/25/31.5
|
16/25/31.5
|
25/31.5/40
|
16/25/31.5
|
16/25/31.5
|
16/25/31.5
|
Rated short circuit
breaking current (kA)
|
16/25/31.5
|
16/25/31.5
|
25/31.5/40
|
16/25/31.5
|
16/25/31.5
|
16/25/31.5
|
Rated short circuit
making current (kA)
|
40/63/80
|
40/63/80
|
63/80/100
|
40/63/80
|
40/63/80
|
40/63/80
|
Operating Duty
|
0-3 min-co-3 min-co
|
0-3 min-co-3 min-co
|
0-3 min-co-3 min-co
|
0-3 min-co-3 min-co
|
0-3 min-co-3 min-co
|
0-3 min-co-3 min-co
|
Operating time
|
< 70ms
|
< 70ms
|
< 70ms
|
< 70ms
|
< 70ms
|
< 70ms
|
Operating Cycles
|
< 2 Cycles
|
< 2 Cycles
|
< 2 Cycles
|
< 2 Cycles
|
< 2 Cycles
|
< 2 Cycles
|
Note: The standard specifications vary from time
to time as our products undergo continuous developments.
|
11 KV DOUBLE BUS BAR VCB
11kV DOUBLE BUS BAR VCB PANEL WITH DUAL SEQUENCE ISOLATOR FOR EACH INCOMING SOURCE
We
supply the Double Bus Bar VCB panel according to the customer
requirements. This kind of double bus bar VCB panel is so advantage
& much worth utilization when you are necessary to take your
distribution through or in between two incoming supply source & as
well so safe to protect your feeder's by safe interlocking provisions
which already equipped inbuilt of the Double Bus Bar PanelFully
Type tested air insulated, extensible double bus bar switchgear
comprises of Horizontal Isolation and Horizontal Draw-out Vacuum Circuit
Breaker, Disconnectors, CTs/PTs (as applicable), earthing switch and
cable box.SALIENT FEATURES
- Fully interlocked VCB, Earthing switch
& Disconnector.
- Motorized disconnector operation
(optional).
- Pressure relief flap for individual HV
compartment. Pressure switches can be given on request.
- Fully insulated / shrouded bus bars
& bus connections.
- Accessibility of compartment:
- Busbar compartment : Tool based.
- Cable compartment : Tool based.
- Switching compartment: Interlock based.
- Cable box suitable for heat shrinkable
PILC/XLPE cables.
- Provision for mounting firefighting
equipment given on request.
- Loss of service continuity category:
LSC2B (as per IEC 62271-200).
- Partition Class: PM (Metallic) (as per
IEC 62271-200).
TECHNICAL DATA
Technical Data of VMAX12 Series 12kV Double Bus bar VCBs
|
Type
|
VMAX12
|
Voltage rating
|
Up to 15kV
|
Frequency
|
50 Hz / 60 Hz
|
Normal circuit current
|
Up to 3150A
|
Normal busbar current
|
Up to 4000A
|
Short circuit breaking current
|
Up to 40kA
|
Short time rating-Main circuit
|
Up to 40kA-3sec, 100kA peak
|
Earth Circuit
|
Up to 40kA-3sec, 100kA peak
|
P.F. Withstand voltage
|
Up to 38kV
|
Impulse withstand voltage
|
Up to 95kV peak
|
Degree of Protection
|
As required
|
Applicable Standards
|
IEC 62271-200 / IEC 62271-100 / IEC 62271-102
|